Tech companies’ use of Pfas gas at facilities may mean datacenters’ climate impact is worse than previously thought

Two kinds of cooling systems are used to prevent the semiconductors and other electronic equipment stored in datacenters from overheating. Water cooling systems require huge volumes of water, and chemicals like nitrates, disinfectants, azoles and other compounds are potentially added and discharged in the environment.

Many centers are now switching to a “two phase” system that uses f-gas as a refrigerant coolant that is run through copper tubing. In this scenario, f-gas is not intentionally released during use, though there may be leaks, and it must be disposed of at the end of its life.

The datacenter industry has claimed that f-gas that escapes is not a threat because, once in the air, it turns into a compound called Tfa. Tfa is considered a Pfas in most of the world, but not the US. Recent research has found it is more toxic than previously thought, and may impact reproductive systems similar to other Pfas.

Researchers in recent years have been alarmed by the ever-growing level of Tfa in the air, water, human blood and elsewhere in the environment. Meanwhile, some f-gases are potent greenhouse gases that can remain in the atmosphere for thousands of years. But f-gasses are lucrative for industry: about 60% of all Pfas manufactured from 2019 to 2022 were f-gas

  • Riskable@programming.dev
    link
    fedilink
    English
    arrow-up
    8
    arrow-down
    43
    ·
    19 hours ago

    WTF? Have you ever been in a data center? They don’t release anything. They just… Sit. And blink lights while server fans blow and cooling systems whir, pumping water throughout.

    The cooling systems they use aren’t that different from any office building. They’re just bigger, beefier versions. They don’t use anything super special. The Pfas they’re talking about in this article are the same old shit that’s used in any industrial air conditioner.

    For the sake of argument, let’s assume that a data center uses 10 times more cooling as an equivalently sized office building. I don’t know about you, but everywhere that I’ve seen data centers, there’s loads and loads of office buildings nearby. Far more than say 10 for every data center.

    My point is this: If you’re going to be bitching about pfas and cooling systems, why focus on data centers (or AI, specifically) when there’s all these damned office buildings? Instead, why don’t we talk about work from home policies which would be an actual way to reduce pfas use.

    This article… Ugh. It’s like bitching that electric car batteries can catch fire, pretending that regular cars don’t have a much, much higher likelihood of catching fire and there’s several orders of magnitude more of them.

    Are Pfas a problem? Yes. Are data centers anywhere near the top 1000 targets for non-trivially reducing their use? No.

    Aside: This is just like the articles bitching about data center water use… Data centers recycle their water! They have a great big intake when they’re done being built but then they’re done. They only need trivial amounts of water after that.

    • triptrapper@lemmy.world
      link
      fedilink
      English
      arrow-up
      26
      ·
      18 hours ago

      Do you have a source on your claim that data centers recycle water? Because these researchers state that 80% of the water is evaporated, and the other 20% is discharged to municipal wastewater facilities.

        • dragonfly4933@lemmy.dbzer0.com
          link
          fedilink
          English
          arrow-up
          1
          ·
          53 minutes ago

          Water isn’t a renewable resource, especially not if the source of water is underground aquifers.

          This is a long post, but these matters could be of grave importance.

          The reason water isn’t always renewable is that statistically, most of the water on earth ends up in the oceans where it gets “trapped”. Sure, some of it evaporates and rains, but most of the rain is over the ocean. Some rain obviously makes it back to land, but most of it still stays in the ocean.

          It’s extra bad if you pump water out of the ground from what are called aquifers. The water in the ground has taken thousands of years to build up, so pumping it out for dumb reasons is not a good idea. We could argue about growing food with ground water, but most people might consider squandering ground water where it is optional to do so, to be short sighted.

          At least some data centers pump water out of aquifers for the purposes of evaporative cooling. This is a method of cooling that is the same as “swap” coolers. It works by taking advantage of the fact that when a liquid undergoes a phase transition, there is a large exchange of energy.

          This is a similar effect to how people can be cooled off by sweating. The sweat evaporates and it leaves the skin cooler, because when the liquid evaporates, heat is taken out of the skin.

          Back to data centers, some pump water out of aquifers, and intentionally evaporate the water to remove heat out of whatever media is used for cooling chips/servers.

          Why do they use this method of cooling? Because it’s cheaper. Typical hvac systems involving compressors consume power and power costs money. So in effect, they are consuming water, an essential and non-renewable resource, in order to avoid having to pay for electricity to cool their servers in a more sustainable way. Evaporative cooling is not necessary to cool a data center. Data centers have been and still are cooled by typical hvac systems which do not consume water in this manner.

          A common retort is “can’t the vapor be condensed back into water?” Yes, but they don’t because that would cost money. As mentioned earlier, creating the vapor consumed heat. To create water, energy would need to be spent to take the heat back out of the water. This is an unavoidable fact of thermodynamics.

          Also, do not confuse evaporative cooling with what some people call a “water” loop. In such a loop, water is being used to move heat from one location to another, in a loop, similar to how water cooled PCs work. This is often done because air has a poor heat capacity, so the size ducts needed to move an adequate amount of air could be too big to be practical, so in these systems, the heat is transferred into water, usually to be sent to a heat exchanger (radiator/heat sink). The water does not undergo a phase transition in a typical water loop. The water merely is hotter when it leaves the so called “air conditioner” and cooler when it leaves the heat exchanger, heading back to the AC. The compressors in the AC units are what is doing the heavy lifting in these style systems.

        • boonhet@sopuli.xyz
          link
          fedilink
          English
          arrow-up
          3
          ·
          7 hours ago

          Not when they keep building them into deserts. Also a lot of the rain falls into the ocean and is then salty. Waste of what is often essentially drinkable water.

    • Siru@discuss.tchncs.de
      link
      fedilink
      English
      arrow-up
      2
      arrow-down
      1
      ·
      18 hours ago

      Wouldn’t the argument being made be that those office buildings already exist, whereas the data centers for AI are being built new? So less of a it’s not a problem in offices and more of a we know this is bad so lets try to not build more of it?

      • Riskable@programming.dev
        link
        fedilink
        English
        arrow-up
        1
        arrow-down
        8
        ·
        16 hours ago

        Does anyone have the data on the total number of data centers that were being built over time? I’m not convinced that AI is causing that many more data centers to be built. From everything I’ve read, is just that they’re putting more GPUs into them.